A map of points is worth more than a list of zones because it says where, how much and how. For each point you record the zone, the precise point on the face, the quantity with its unit and the instrument; for those who want more, also the plane and the technique. The map is compared with the one from the previous session. Where to inject remains the doctor's decision: the map records, it does not direct.
Below you will find what to record, what the texts say about recording injection sites, and how to use the map in Fibonacci.
Why a map is worth more than a list of zones
"Cheekbones" does not say how many points, how much product and where. Two points recorded, each with its quantity, do say it.
An example from a different field shows what makes a register readable. A Japanese study analysed 299,413 sessions and 417,590 hyaluronic acid injection sites in 110 clinics. This was possible because each site was recorded as a separate entry, chosen from a fixed menu of 14 anatomical regions, in the shared electronic medical record. The 2020 data were excluded from the site analyses because uniform site classification arrived in 2021 (Tamura et al., 2026 (opens in a new tab)). The lesson holds even for a single practice: same list of zones, one entry per site, and after years the data can be compared.
Then there is the reason that matters most. A group of experts from the Asia-Pacific region, in 2022, defined delayed inflammatory reactions to hyaluronic acid filler as large, painful, red nodules with surrounding oedema, appearing at least 14 days after injection. Among the risk factors the group lists a filler with greater immunogenic potential, breaches of asepsis rules and incorrect injection technique, and links technique to knowledge of anatomy, including depth and injection plane (Corduff et al., 2022 (opens in a new tab)). When a nodule appears in a zone weeks later, the map lets you answer four questions: which product, how much, with which instrument, at what depth. If the answer is written down, you assess the rest. If it is not, it cannot be recovered.
What to record for each point
| Data | Why |
|---|---|
| Zone and point, with the side | To find it again at the next session and at follow-up |
| Quantity, with the unit | The units of one product do not convert into those of another (see below) |
| Instrument (needle, cannula, microneedles) and gauge | Injection instruments are among the aspects of use the manufacturer must consider |
| Plane and technique | Technique is among those same aspects; depth and plane appear among the knowledge the experts cite regarding technique |
| Product and batch | These are recorded at session level; see batch traceability |
| Off-label use, with the reason | See off-label drug |
That instrument, technique and maximum quantity per site are part of the picture is stated by Annex IV of Regulation 2022/2346, at point 3.1: the manufacturer must take into account the specific anatomical site of injection and aspects related to use, including injection technique, injection instruments, the maximum quantity injected depending on the site and technique, and the possible repetition of injections (point 3.1, letters f and j (opens in a new tab)). These are data that whoever injects knows, and that the medical record must be able to return.
On units, an official source is explicit. The approved US label for Botox (in the version for therapeutic indications) states that the product's units are specific to the preparation and measurement method, that they are not interchangeable with other botulinum toxin products and cannot be compared with or converted into those of another product (FDA, BOTOX label (opens in a new tab)). In the record, therefore, the product name must be written next to the number. The same label also shows how an official source describes a site: for therapeutic indications, diagrams with marked sites, the number of sites per muscle and the units per site; for one of them, also a rule on side (all muscles on both sides, with half the sites on the left and half on the right, except one injected on the midline). It is an example of the format, not a guide for a face: for each product, the reference is its own label.
How the map works in Fibonacci
In the treatment form, under Body-map and treated areas, choose between two surfaces. With Photo you mark with a single click on the frontal portrait, male or female, which offers 76 areas of the face. With 3D you mark with a double click on the full-body model, face included: you drag to rotate, the wheel zooms in, and the double click is there so you do not mark anything by mistake. The dot on the 3D model stays where you clicked, not at the centre of the area.
Three things to keep in mind:
- the model's sex is a single setting and applies to both surfaces; on the portrait it also changes where the dots fall, because the two faces have different proportions;
- the exact points apply to the model you placed them on: changing model moves the dot to the centre of the area, while the areas recorded in the medical record stay the same;
- dots and the list of areas below the map are the same thing seen in two ways: if you place one, the area enters the list; if you choose it from the list, the dot appears.
On the point you write the treatment and the quantity, with the unit, in free text. In a separate, optional section of its own, How it was done, there are four drop-downs with a closed vocabulary: instrument (needle, cannula, microneedles or roller, other), gauge (from 18G to 34G), plane (supraperiosteal, subgaleal, subfascial, subcutaneous, deep dermal, superficial dermal) and technique (bolus, microbolus, retrograde, anterograde, fanning, linear). No drop-down suggests the right value for the zone and none warns you if a combination is unusual: per-zone tables exist in the literature and stay outside the program, because they would be a clinical indication. A point without these fields remains valid. Off-label use is a checkbox on the treatment record, not on the individual dot, and it asks for the reason.
If you dictate the session with dictation, the program fills in product, quantity, batch and off-label, but writes the recognised zones at the end of the notes in the form [aree dettate: ...]: to turn them into dots there is Aree rilevate dal testo, which suggests labels for keywords, and Auto-estrai aree dal testo, which sends the notes to the extraction service and adds the areas to the existing dots. In both cases the action is yours: nothing enters the medical record on its own.
Comparing with the previous session
For a touch-up you reselect the areas on the map, or you write the session in words and press Auto-estrai aree dal testo. To see the history there is the Mappa trattamenti, in the Treatment history section: for each area it shows how many times it has been treated, and the colour indicates the most frequent product category. Clicking an area filters the history below to that zone, and the page flags an imbalance between left and right when the counts on the two sides diverge. The number is that of treatments recorded on the area, not the quantity of product, and the map has no period selector: it shows the entire history.
On the face and on the body: the photo is quicker for the frontal face; the 3D model is useful when the areas are not on the frontal portrait. From the Altro button in the medical record you get Esporta PDF (summary of treatments) and Esporta CSV (the same thing as a table); the file for a single session is downloaded from the session row (recording a treatment, face analysis).
What the map does not say
It does not say where to inject and it does not compare your scheme with a "correct" one: the choice is the doctor's. It does not measure anything on the face. The count on the history map is not a dose. What it gives back is what you wrote, in the place where you will look for it: the guide what to write in the medical record after an injectable treatment and the article on fillers and botulinum toxin in the medical record describe the other entries of the session; the follow-up after treatment is the moment when the map is read again.