Batch traceability is the ability to answer, in a few minutes and in writing, a single question: which patients received this batch? You can only answer if, at every session, you wrote down product, batch, expiry and quantity, and if that data can be searched across all records at once.
Below: why it matters, what you always write down, how to avoid copying by hand, what the legal texts on devices say and how to prepare for a recall. The legal part concerns devices (fillers, equipment); for botulinum toxin, which is a medicine, the rules on medicines apply: the device regulation excludes them (Article 1(6)(b)).
Why a batch matters
Three situations, all alike in one respect: they arrive without warning.
A product recall. The manufacturer or the authority announces that a batch has a problem. You need to know whether you used it, and on whom.
An unusual reaction. If a patient has a reaction you suspect is linked to the product, the batch is the piece of data the manufacturer uses to trace the lot. Italian Legislative Decree 137/2022, Article 10 (opens in a new tab), provides that healthcare professionals who detect a serious incident involving a device, even a suspected one, must report it to the Ministry of Health (paragraph 2), that the report must also be sent to the manufacturer or its authorised representative (paragraph 5) and that complaints must be notified to the manufacturer (paragraph 6). Without the batch, the report is weaker.
A dispute. If someone questions what was injected, the session entry is the answer.
What to always write down
Six data points for every product injected:
| Data point | Why |
|---|---|
| Product, with the trade name | A batch only makes sense within its product |
| Batch | The search key |
| Expiry | Distinguishes an administration within shelf life from one after it |
| Quantity administered | Tells you how much of that batch went to that patient |
| Patient | From here you trace to the batch, and from the batch to the patients |
| Date of the session | To place the batch in time |
When the product has a UDI (unique device identifier), add it. Regulation 2017/745, Article 27(9) (opens in a new tab), requires healthcare institutions to store and keep the UDIs of class III implantable devices; for other devices it says Member States encourage healthcare institutions, and may require them, to do so, and encourage healthcare professionals, and may require them. In Italy, Italian Legislative Decree 137/2022 (Article 15(1) (opens in a new tab)) establishes that institutions and healthcare professionals are required to record and keep the UDI of the devices they have received, "in accordance with provisions" to be laid down by decrees of the Minister of Health. The text refers to those decrees: check on the Ministry's portal whether they have been adopted and what they require.
For fillers there is one more indication, from the manufacturer. In Implementing Regulation 2022/2346, Annex IV, the instructions for use of a filler include a sheet to be given to the patient, which has a part for recording the site, number and volume of injections for each consumer: the manufacturer recommends that the healthcare professional complete it (EUR-Lex (opens in a new tab)). It is a recommendation, not a legal obligation. Your record can do the same job, if the data is there.
In Fibonacci, when recording a session you fill in batch number, expiry and, where needed, dilution and UDI. On these fields the program records and does not calculate: if a data point appears inconsistent it warns you, but does not block saving (recording a treatment).
Label and code: where to find the batch and how to save it without copying it
Copy the batch exactly as printed on the packaging, without adding spaces or hyphens. For a search, A1234-B and A1234 B are two different batches.
To avoid copying by hand, the program has Read from packaging. You can read the 2D code with a USB scanner (any that types like a keyboard), with your phone or tablet camera, or from a photo. The code yields batch, expiry, serial number and product code (GTIN). The product is recognised from the AIC code for toxins, and for fillers and devices from stock, from the second box loaded onwards; the first time it shows "Not recognised" and you choose the product by hand. If the printed date has passed, "Expired packaging" appears. The image does not leave the device. Check the data against the box and press Use this data.
Stock has its own page for deliveries, expiring batches and stock levels (stock). The balance recalculates itself by subtracting what sessions with the same product and the same batch have declared: if the batch in a session is written one way and on delivery another, the program sees two batches.
From batch to patient, and from patient to batch
The search works in two directions, and they answer two different questions.
From batch to patients. On the Stock page, the Who received it tab is a single-field search: type the batch and you get the list of sessions in which it was used, with patient, date, quantity and recorded expiry. The search runs across all the practice's patients in a single query (batch traceability). A warning flags sessions with a product but no batch number: the search does not see them.
From patient to batch. This is the simpler direction: open the session and read. From the session entry you download the PDF file with product, batch, expiry, quantity, areas, technique, consents, photos and access logs. If the session had a complication, it is recorded from the same entry and stays linked to that product and that batch.
A batch recall: who to notify and how
A recall opens with a manufacturer's notice (the field safety notice under Article 89) or with a communication from the authority. Fibonacci does not decide whether a batch should be recalled: the manufacturer or the Ministry does. From the Who received it list you can:
- export the list to CSV;
- prepare a text to send to patients. The program sends nothing: you copy it and use it through your own channel. The text deliberately does not state the reason for contact, because anyone holding the phone can read an SMS: the reason is given by voice.
Contacting patients is a clinical communication and the practice makes it, not an automation. When you call a patient, what you need to know (what was done and when) is in the record.
If you suspect an adverse event linked to the batch, the report must be recorded in the patient's file, in the outcomes and complications section, which has a field for product and batch. For devices there is also the supply chain: the regulation (Article 25 (opens in a new tab)) says economic operators must be able to identify to the authority any healthcare institution or healthcare professional to whom they have directly supplied a device: this means whoever sells you the product knows they sold it to you, and a notice can reach you from there. Keep invoices and purchase orders.
A simple batch log
If you work on paper today, a sheet with these columns is enough to answer a recall:
| Date | Patient | Product | Batch | Expiry | Quantity | Area |
|---|---|---|---|---|---|---|
| 12/03/2026 | Example patient A | "Product Alpha" | LOT-0000-X | 09/2027 | (units or mL) | (sites) |
The data is fictitious. The sheet works if it is sorted by date and if the batch is always written the same way. The safest way is for the program to write it for you.
The mistakes that cost you
- Batch entered in different formats in different sessions. Agree on a single way of transcribing it in the practice.
- Batch left blank because "it's always the same one". That is the case where traceability matters most, and it isn't there.
- Expiry not recorded. Without it, you cannot distinguish an administration within shelf life from one after it: it is a data point that protects you too.
The program does not force you to write the batch. But it is the data point with which you answer a recall, and its absence is only noticed when you need it. The page on the website summarising the legal texts is product traceability. How to write a full treatment entry with filler or toxin is in the article on what to write in the record after a filler or a toxin.